The following tables contain the specifications for the Real Freedom Fiber Antenna
            Extender.
     View the Real Freedom
                Fiber Antenna Extender datasheet.
            View the Real Freedom
                Fiber Antenna Extender datasheet.
        Environmental 
            
         
            Table 1. Operating and storage specifications
                            
                                | Parameter | Specification | 
                        
                            
                                | Humidity | 95% non-condensing | 
                            
                                | Ingress | Weatherproof to IP67 | 
                            
                                | Operating/storage temperature | 14° to 149°F / -10° to +65°C | 
                        
            
        
        Fiber inputs (fiber base unit)
            
            Table 2. Fiber base unit fiber input specifications
                        
                            | Parameter | Specification | 
                    
                        
                            | Type | SMPTE 311M single mode (single mode APC available on
                                request) | 
                        
                            | Connector | LEMO FXW.3K.93C.TLM | 
                    
            
        
        Fiber outputs (fiber remote unit)
            
            Table 3. Fiber remote unit fiber output specifications
                        
                            | Parameter | Specification | 
                    
                        
                            | Type | SMPTE 311M single mode (single mode APC available on
                                request) | 
                        
                            | Connector | LEMO EDW.3K.93C.TLC | 
                    
        
  
    Physical (fiber base unit)
        
        
        Table 4. Fiber base unit size, weight and mounting specifications
                    
                        | Parameter | Specification | 
                
                    
                        | Size (W x H x D) | 3.93 x 5.82 x 1.9 in / 100 x 148 x 48.38 mm | 
                    
                        | Weight | 2.75 lb. / 1.251 kg | 
                    
                        | Mounting | Pole clamp with ¼-20 fitting | 
                
        
    
        Physical (fiber remote unit)
            
            Table 5. Fiber remote unit size, weight and mounting specifications
                        
                            | Parameter | Specification | 
                    
                        
                            | Size (W x H x D) | 2.95 x 5.47 x 1.14 in / 75 x 139 x 29 mm | 
                        
                            | Weight | 1.8 lb. / 0.82 kg | 
                        
                            | Mounting | Pole clamp with ¼-20 fitting | 
                    
        
 
    Power (fiber base unit)
        
        
        Table 6. Fiber base unit power specifications
                    
                        | Parameter | Specification | 
                
                    
                        | DC supply | 9–36 V DC, via LEMO | 
                    
                        | DC supply connector | LEMO 0K 4-Pin CLL.0K.304.CLLP | 
                    
                        | DC fiber remote power | 36 V DC to IEC/EN 60950-1 | 
                    
                        | LED | Green - Power On Comms OK, Red - Fault No Comms | 
                
        
    
    Power (fiber remote unit)
        
        
        Table 7. Fiber remote unit power specifications
                    
                        | Parameter | Specification | 
                
                    
                        | Connector | Via fiber connector or LEMO 0K 2-pin | 
                    
                        | Aux DC supply | 9–36 V DC (required for > 2 km fiber length) | 
                    
                        | LED | Green - Power On Comms OK, Red - Fault No Comms | 
                
    
    RF inputs (fiber remote unit)
        
        Table 8. Fiber remote unit RF input specifications
                    
                        | Parameter | Specification | 
                
                    
                        | Number of inputs | 2 | 
                    
                        | Impedance | 75 Ohm | 
                    
                        | Frequency range | 50–850 MHz | 
                    
                        | Connector | BNC (F) | 
                
    
        RF outputs (fiber base unit)
            
            Table 9. Fiber base unit RF output specifications
                        
                            | Parameter | Specification | 
                    
                        
                            | Number of outputs | 2 (2 x 6 with optional Active UHF Splitter) | 
                        
                            | Impedance | 75 Ohm | 
                        
                            | Frequency range | 50–850 MHz | 
                        
                            | Connector | BNC (F) |