Mounting procedure: two fiber base units side by side
To mount two fiber base units side by side, you will require 1RU (1.75 inches, 44.45 mm) of vertical rack space and a Real Freedom Joining Kit - Rack Unit (20006-9-031).
- Attach the Joining Bar Top (Rack Unit) to the right side of the first
fiber base unit using two M4 x 20 Phillips screws.
You need to install this bar using the top two screw holes as shown in the following image.
- Attach the Joining Bar Bottom (Rack Unit) to the left side of the
other fiber base unit using two M4 x 20 Phillips screws.
You need to install this bar using the bottom two screw holes as shown in the following image.
- Place the fiber base units together and connect the joining bars using two M4 x
25 Phillips screws.
- Install the connected units at the desired location in the equipment rack and secure to the vertical uprights using four rack screws.