Mounting procedure: two fiber base units side by side

To mount two fiber base units side by side, you will require 1RU (1.75 inches, 44.45 mm) of vertical rack space and a Real Freedom Joining Kit - Rack Unit (20006-9-031).

  1. Attach the Joining Bar Top (Rack Unit) to the right side of the first fiber base unit using two M4 x 20 Phillips screws.

    You need to install this bar using the top two screw holes as shown in the following image.

  2. Attach the Joining Bar Bottom (Rack Unit) to the left side of the other fiber base unit using two M4 x 20 Phillips screws.

    You need to install this bar using the bottom two screw holes as shown in the following image.

  3. Place the fiber base units together and connect the joining bars using two M4 x 25 Phillips screws.

  4. Install the connected units at the desired location in the equipment rack and secure to the vertical uprights using four rack screws.